MTA / NYCT: Sandy Power Repairs at 12 Circuit Breaker Houses, 3 Substations, and 3 Fan Plant EDRs in Various Locations (Contract P36312) – CCM & and Inspection Services

Tectonic is providing comprehensive Construction Management and Inspection Services for the monumental rebuilding of eighteen (18) electrical infrastructure sites that power New York City’s expansive metro and rail transit network. This complex $75 million project delivers extensive repairs and upgrades to twelve (12) critical Circuit Breaker Houses (CBHs), three (3) Substations, and three (3) Fan Plant Electrical Distribution Rooms (EDRs) across the metro region.

These facilities constitute the heart of the transit power system – without them, the trains don’t run, stations go dark, and communications fail. After decades of heavy use, they require urgent rehabilitation to handle soaring electricity demands and ensure the region’s economic vitality. Tectonic is providing construction management and inspection services to coordinate all facets of this intricate rebuild project per MTA guidelines and procedures. Our expert staff are interfaced with a diverse project team encompassing civil, structural, mechanical, electrical, traction power, environmental, and other specialty engineers to integrate complex interdisciplinary work. Concurrently, we foster smooth partnerships across multiple stakeholders such as
construction contractors, design consultants, city agencies like ConEd, and other entities with intersecting projects. Scope of work includes:
• Various repairs and replacements to infrastructure components at multiple pump rooms and fan plants, including roofs, siding, doors, lighting, HVAC, cabling, flooring, terminal boxes, battery boxes, breakers, and concrete. (CBH-56, CBH-58, CBH-75, CBH-213A, CBH278 and 279, CBH-284, CBH-304, CBH-538, CBH-545, CBH-548, and CBH-588)

• Replace high-tension switchgear, transformers, batteries, battery charger, door, battery distribution panel, and interface connections at Substation #204 Edgemere.

• Replace two high tension switchgears, one transformer, one grounding device, door, door frame, and interface connections at Substation #117 Rockaway Park.

• Replace battery, battery charger, emergency alarm, door, door frame, and interface connections at Substation #55 Brighton/West 8th Street.

• Repair cracked concrete and seal cable penetrations at Fan Plant #7230 Clark Street manholes, fan plant, and pump room.

• Replace cabling, provide temporary power, install cable limiters and seals at Fan Plant #8107 FDR Drive property line box and equipment distribution room. Coordinating with Con Ed.

• Similar replacements, temporary power provisions, cable limiters, seals at Fan Plant #8104 property line box and equipment distribution room. Coordinating with Con Ed

Become a prequalified vendor

Become a prequalified vendor

INSTRUCTIONS

Companies interested in providing professional services or construction services to Tectonic must be prequalified. Firms that provide products or other services are not required to be prequalified.

  • Thank you for your interest in doing business with Tectonic:
  • Please answer all questions and provide all requested information. If a question is not applicable, indicate as “N/A” and provide an explanation if necessary.
  • Supplemental information sheets should be used to provide additional information that does not fit on the form.
  • Clearly indicate at the top of the supplemental information sheet which section of the questionnaire it references.
  • After the questionnaire is fully reviewed for completeness, please click on the “Submit” button.
  • Any questions regarding this form can be sent to prequal@tectonicengineering.com.

GENERAL

Maximum file size: 33.55MB

Upload a copy of your certificate(s) and/or screenshot(s) verifying the above reported status. * If you do not have any verifications, please be sure to check the box above for None or Not Applicable*

PRIMARY (CORPORATE) OFFICE INFORMATION

(Use this format: mm-dd-yyyy)

PRIMARY CONTACT

SECONDARY CONTACT

CLAIMS CONTACT

OFFICERS

.

STOCKHOLDERS

(include only those owning 5% of more of stock. Attach a supplemental sheet if needed.)

COLLECTIVE BARGAINING AGREEMENTS

(Identify union affiliations)
Do you have experience with projects that require Certified Payroll and Davis Bacon Wage Rates?

SERVICE CAPABILITIES

.

SERVICES PROVIDED

(Select all services that apply)

Maximum file size: 5MB

STAFFING

.

OFFICE LOCATIONS & REGIONS SERVED

(Including primary office)


LITIGATION / CONTRACT DISPUTES

List any judments, arbitrations, liens, insurance claims, or lawsuits the firm has been subject to within the past 5 years. If there are none, respond by saying there were none.

Maximum file size: 5MB

CRIMINAL BACKGROUND INFORMATION

Has the firm, any affiliate, or any of the current or former principal owners, stockholders, or officers or managerial employees:

Insurance Coverage

State your standard coverage limits in COLUMN 2 below.

POLICY

Occurrence (or claim) limit

Aggregate limit

GCL

Auto

Umbrella / Excess

Pollution / Liability

Workers Compensation

Professional Liability

Cyber / Network Security Liability


Health & Safety

Maximum file size: 33.55MB

Health & Safety (Cont.)

If Yes, does the training include:

Health & Safety (Cont.)

Health & Safety (Cont.)

Provide the following information for the last 3 years. You must respond to all questions even if your firm is not required to maintain OSHA logs.

  YEAR (most recent 3 years)

  Current Year

  Prior Year

  Prior Year

Worker's Compensation
Experience Modification Rate (EMR)


Number of Fatalities
(list any, explain in Supplemental Information field at the end of this form.)


Lost Work Day Incident Rate
(total lost-time recordable cases x 200,000 / total hours worked.)


OSHA Recordable Incident Rate
(total OSHA recordable cases x 200,000 / total hours worked)


Total Number of Hours Worked
(per occurrence)


The following upload fields allow for uploading of multiple files.
  1. To upload multiple files please click-and-hold the CTRL key and left-click with your mouse.
  2. Once you have selected the file(s) hit the "Open" button on the the dialog box.

Maximum file size: 10MB

Sending

Special Inspection Feedback Form

Special Inspection Feedback Form

Section

1 = Not reliable and 10 = Very reliable
1 = Not well and 10 = Extremely well
1 = Not Satisfied and 10 = Extremely Satisfied
1 = Not satisfied and 10 = Very satisfied

Section

1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied

Section

(Please fill only if you answered "Yes" in the previous question)
Sending

Service Evaluation

Service Evaluation

Section

Your name
The company you're working with
A contact phone number if you would like to be contacted (In this format XXX-XXX-XXXX)
Feel free to express your views of TECTONIC service.
Sending

Enter your search criteria below: