Child Care Center (CCC) Outdoor Play Area (OPA) Testing and Remediation

This project resulted from renovation work, involving exterior building envelope restoration work, that caused Poly-Chlorinated Biphenyl (PCB) -laden debris (in the form of waste caulk) to fall throughout the Federal courthouse plaza, including into the playground of the employee’s day care center. This project had a sensitive population at risk, and numerous concerned parties. The falling debris resulted in site-wide contamination above background levels and both state and Federal regulatory triggers. The regulatory framework included satisfying New Jersey Department of Environmental Protection (NJDEP) and Federal Toxic Substances Control Act (TSCA) clean-up requirements simultaneously. Tectonic provided reviews, inspection, and testing services to delineate the extent of residual PCBs.

The site is located within a Federal compound of a large city; this, and the security issues made the Remedial Investigation (RI) a challenge. Tectonic also ensured the testing regimens conformed to the TSCA evaluation procedures and all samples were analyzed at a NJ-authorized contract laboratory. Tectonic delineated the horizontal and vertical extent of PCBs in the soil and unitary play surface.

Become a prequalified vendor

Become a prequalified vendor

INSTRUCTIONS

Companies interested in providing professional services or construction services to Tectonic must be prequalified. Firms that provide products or other services are not required to be prequalified.

  • Thank you for your interest in doing business with Tectonic:
  • Please answer all questions and provide all requested information. If a question is not applicable, indicate as “N/A” and provide an explanation if necessary.
  • Supplemental information sheets should be used to provide additional information that does not fit on the form.
  • Clearly indicate at the top of the supplemental information sheet which section of the questionnaire it references.
  • After the questionnaire is fully reviewed for completeness, please click on the “Submit” button.
  • Any questions regarding this form can be sent to prequal@tectonicengineering.com.

GENERAL

Maximum file size: 33.55MB

PRIMARY (CORPORATE) OFFICE INFORMATION

(Use this format: mm-dd-yyyy)

PRIMARY CONTACT

SECONDARY CONTACT

OFFICERS

.

STOCKHOLDERS

(include only those owning 5% of more of stock. Attach a supplemental sheet if needed.)

COLLECTIVE BARGAINING AGREEMENTS

(Identify union affiliations)
Do you have experience with projects that require Certified Payroll and Davis Bacon Wage Rates?

SERVICE CAPABILITIES

.
Sending

SERVICES PROVIDED

(Select all services that apply)

Maximum file size: 5MB

STAFFING

.

OFFICE LOCATIONS & REGIONS SERVED

(Including primary office)

LITIGATION / CONTRACT DISPUTES

List any judments, arbitrations, liens, insurance claims, or lawsuits the firm has been subject to within the past 5 years. If there are none, respond by saying there were none.

Maximum file size: 5MB

CRIMINAL BACKGROUND INFORMATION

Has the firm, any affiliate, or any of the current or former principal owners, stockholders, or officers or managerial employees:

Insurance Coverage

State your standard coverage limits in COLUMN 2 below.

POLICY

Occurrence (or claim) limit

Aggregate limit

GCL

Auto

Umbrella / Excess

Pollution / Liability
Workers Compensation
Professional Liability
Cyber / Network Security Liability

Health & Safety

Maximum file size: 33.55MB

Health & Safety (Cont.)

If Yes, does the training include:

Health & Safety (Cont.)

Health & Safety (Cont.)

Provide the following information for the last 3 years. You must respond to all questions even if your firm is not required to maintain OSHA logs.
  YEAR (most recent 3 years)

  Current Year

  Prior Year

  Prior Year

Worker's Compensation
Experience Modification Rate (EMR)
Number of Fatalities
(list any, explain in Supplemental Information field at the end of this form.)
Lost Work Day Incident Rate
(total lost-time recordable cases x 200,000 / total hours worked.)
OSHA Recordable Incident Rate
(total OSHA recordable cases x 200,000 / total hours worked)
Total Number of Hours Worked
(per occurrence)
The following upload fields allow for uploading of multiple files.

  1. To upload multiple files please click-and-hold the CTRL key and left-click with your mouse.
  2. Once you have selected the file(s) hit the "Open" button on the the dialog box.

Maximum file size: 10MB

Maximum file size: 10MB

Maximum file size: 10MB

Quality Assurance (QA) / Quality Control (QC) Practices

Special Inspection Feedback Form

Special Inspection Feedback Form

Section

1 = Not reliable and 10 = Very reliable
1 = Not well and 10 = Extremely well
1 = Not Satisfied and 10 = Extremely Satisfied
1 = Not satisfied and 10 = Very satisfied

Section

1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied

Section

(Please fill only if you answered "Yes" in the previous question)
Sending

Service Evaluation

Service Evaluation

Section

Your name
The company you're working with
A contact phone number if you would like to be contacted (In this format XXX-XXX-XXXX)
Feel free to express your views of TECTONIC service.
Sending

Enter your search criteria below: