Amtrak Gateway Tunnel, Hudson Yards Development

Tectonic provided construction inspection, materials testing and construction phase geotechnical engineering services for the Amtrak Tunnel Casing at the Hudson Yards Development project on the west side of Manhattan. The Amtrak Tunnel Casing which, will be located within the LIRR Storage Yard, is being constructed in advance of the main gateway project to ensure access to this area prior to construction of the main platform that will cover over the West Side Storage Yard to accommodate the build out of Hudson Yards.

Tectonic provided geotechnical engineering and special inspection services associated with the rock anchor tied back secant pile walls and the cut and cover box tunnel for the Amtrak Casing as well as for the future buildings. Special inspections included Concrete Testing for Foundation & Superstructure, Dynamic & Static MOE Testing, Shrinkage Testing, Mass Concrete Monitoring, Filigree inspections, Structural Steel Welding & Bolting, SOE Inspections, Post Tensioning, Reinforced Masonry, Fireproofing and Firestopping.

Responsibilities included resident engineering for technical oversight of geotechnical construction work, contract administration, technical inspections, QA/QC on-site field testing of materials, field measurement and collection of data for contractor payments, coordination of contractors scheduling, attendance at on-site progress meetings, coordinating with outside involved agencies, assist with preparation of RFI’s, preparation of daily inspection reports and monthly progress reports, record keeping and as-built plan preparation.

At full build-out, the mixed-use development will include 16 high rise buildings containing more than 12.7 million SF to accommodate residential, commercial and retail development. A platform will be constructed over MTA Long Island Railroad (LIRR) West Side Storage Yard to accommodate the buildings and infrastructure.

Special Inspection Feedback Form

Special Inspection Feedback Form

Section

1 = Not reliable and 10 = Very reliable
1 = Not well and 10 = Extremely well
1 = Not Satisfied and 10 = Extremely Satisfied
1 = Not satisfied and 10 = Very satisfied

Section

1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied

Section

(Please fill only if you answered "Yes" in the previous question)
Sending

Service Evaluation

Service Evaluation

Section

Your name
The company you're working with
A contact phone number if you would like to be contacted (In this format XXX-XXX-XXXX)
Feel free to express your views of TECTONIC service.
Sending

Enter your search criteria below: