Mobile Laboratory at Tappan Zee Bridge Replacement

Tectonic is providing Quality Control (QC) services for the construction of the new Tappan Zee Hudson River Bridge as sub-consultant to Tappan Zee Constructors, LLC – (TZC), the team of Principal Participants Fluor Enterprises, Inc., American Bridge Company, Granite Construction Northeast, Inc. and Traylor Bros., Inc. As an integral part of the TZC team, Tectonic is responsible for all components of special inspections and materials testing, Including:

  • Pile Driving Inspection & Monitoring
  • Steel Inspection and Non-Destructive Testing of Steel Components
  • Geotechnical Inspection of Earthwork, Subgrades & Backfill
  • CIP & Precast Concrete Inspection & Testing
  • Asphalt Paving Inspection & Testing
  • Establishment of an On-Site Materials Testing Laboratory

The existing bridge is an essential component of the regional roadway network connecting Rockland County with Westchester County and providing integral access to the New York Metropolitan Area. The new Tappan Zee Hudson River Crossing is designed for a 100-year service life and will be mass-transit-ready. It features twin three-mile structures, each with 1,200-foot cable-stayed main spans and 350-foot steel girder approach spans. The new bridge provides eight general traffic lanes, emergency lanes, extra-wide shoulders for express bus service, a dedicated bicycle and pedestrian path on the northern span, and scenic overlooks with anti-climb fencing and security cameras. A new toll plaza will include at least three highway-speed E-Z Pass lanes. The project also includes plans for the approximately 35 existing buildings associated with the bridge. The design-build approach produced a savings of $1.7 billion compared with original state and federal cost estimates and is scheduled for completion in 2018.

Special Inspection Feedback Form

Special Inspection Feedback Form

Section

1 = Not reliable and 10 = Very reliable
1 = Not well and 10 = Extremely well
1 = Not Satisfied and 10 = Extremely Satisfied
1 = Not satisfied and 10 = Very satisfied

Section

1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied
1 = Not Satisfied and 10 = Very Satisfied

Section

(Please fill only if you answered "Yes" in the previous question)
Sending

Service Evaluation

Service Evaluation

Section

Your name
The company you're working with
A contact phone number if you would like to be contacted (In this format XXX-XXX-XXXX)
Feel free to express your views of TECTONIC service.
Sending

Enter your search criteria below: